Sergeant/Driver Operator:
1. position apparatusFirefighter:
2. engage pump--if warranted, use tank water
3. connect 5" supply line to intake
3. signal plug operator to open hydrant
4. connect lines to discharges on deck gun
5. charge deck gun on command
6. supply pump with hydrant water when available
1. pull 5" line to hydrantCompany Commander:
2. make connection to hydrant
3. open hydrant on signal from driver/operator
4. proceed to engine
5. proceed to deck gun
6. rotate nozzle in the proper direction and height
7. direct stream on the most effective area
1. establish commandWhen operating as a four person company the firefighter is responsible for the duties deemed necessary by the commanding officer.
2. set-up deck gun operation
3. direct use of deck gun