ENGINE IS FIRST ON THE SCENE
Sergeant/Driver Operator will:
1. position apparatusFirefighter will:
2. don bunker gear and SCBA
3. obtain pike pole, rope bag, and forcible entry tool
4. check all standpipe outlet caps and valves below fire floor (if standpipe)
1. obtain highrise pack (or two 1 3/4" doughnut rolls and nozzle)Company Commander will:
2. proceed with officer to the floor below the fire
1. establish or pass off command, make size-up, give initial report, and develop attack plan as per REVASWhen operating as a four person company the firefighter is responsible for the duties deemed necessary by the commanding officer.
2. direct other incoming units and implement plan until relieved of command
3. back-up firefighter on the attack line or pull a second pre-connect
4. obtain 1 /34" highrise pack (or as apparatus is equipped)
5. proceed to lobby and obtain futher information from occupants/hall personnel
6. direct other incoming units and implement proper highrise procedure
7. proceed to floor below fire and set up operations