ENGINE IS SECOND ON SCENE
Sergeant/Driver Operator will:
Firefighter will:
1. pull 5" hose to hydrantCompany Commander will:
2. make hydrant connect
3. open hydrant on signal from driver operator
4. straighten out 5" line
5. report to driver operator
6. take SCBA bottles to staging area (if using carriers take four)
7. report to sector/company officer
1. pull two 2 1/2" lines
2. connect 2 1/2" lines to standpipe connection
3. check for gated wye or end of hose when hoisting lines (when no standpipe is present)
4. obtain highrise pack or doughnut rolls and nozzles
5. proceed to the interior staging commander usually two floors below fire floor or operations sector commander
When operating as a four
person company the firefighter is responsible for the duties deemed necessary
by the commanding officer.